About LuxMed Biosafety Cabinet Controller
Features Microprocessor Controller based with LCD Display, Menu Control, automatic filter alarm system, have the following Menu Controlled Features: HEPA Filter Alarm after programmed hours with ON/OFF. Password (Programmable) for Authorized Operation. Initial Self Cleaning Cycle. Total HEPA Filter run time. HEPA Filter life display and alarm. Audio Visual Door Unsafe Alarm, if door is at incorrect operating height. Real Time Clock. UV Timer. Total UV used Time. Door Safe Position Alarm sounds if door is raised above correct operating height ( Sensor Model). Display in flow velocity (Sensor Model-Uni). Cabinet Temperature display (Sensor Model-Uni and Duo). Display in Down flow velocity (Sensor Model-Duo). U.V. Light in work chamber Inter Locked with Door & Fluorescent Lights i.e. it switches ON only when door is closed, and automatically switches OFF fluorescent lights. 30 minutes Auto Off Timer. MEMS Air Velocity Sensor Model : >> Dual Sensor (Duo).>> Single Sensor (Uni). >> Without Sensor. Copyright 2020-2021 Luxlighting. All rights reserved. The information in this document is subject to change without notice. Luxlighting, the Luxlighting logo and Luxlighting are registered trademarks of Luxlighting Technology Pvt. Ltd. India Inflow : 0.1 4.0 m/s (20 to 800 fpm). Down flow: 0.1 4.0 m/s (20 to 800 fpm). Key Operation of Bio - Safety Cabinet Key Descriptions: Menu : Press to open the Menu & edit the settings SET : To Exit the menu. Up : Used for Up Counter for all type of setting Dn : Used for Down Counter for all type of setting Direct access key : System ON / OFF, Light ON-OFF, UVT ON-OFF, Fan ON-OFF, EXHAUST. Air Velocity Sensor Interface On board 4nos SSR 4amp for each item : Fan, Light, UVT, Virus Burn Heater
Screen-1 1. L: 0.0 M/S : Air velocity measured in for lower flow meter / second, also the high and low alarm linked with the blower air velocity generated. 2. L: 0.0 F/M : Air velocity measured in for lower flow foot / minute, also the high and low alarm linked with the blower air velocity generated. 3. U: 0.0 M/S : Air velocity measured in for Upper flow meter / second, also the high and low alarm linked with the blower air velocity generated. 4. U: 0.0 F/M : Air velocity measured in for Upper flow foot / minute, also the high and low alarm linked with the blower air velocity generated. 5. Ab_Tp : display the room temperature. 6. [ON] system ON indicator. 7. Date and time display at the top of display screen. 8. [SAFE] / [UNSAFE operation based on the front door position and internal air velocity pressure conditions.