COMBO Deal : Ethylene Oxide Sterilizer (ETO) and Drying Cabinet Specification

  • Type
  • Combo ETO Sterilizer & Drying Cabinet
  • Chamber Size
  • 1200mm x 600mm x 600mm
  • Chamber Thickness
  • 5 mm (Standard)
  • Outer Size
  • 2000mm x 1200mm x 1600mm
  • Compressed Air
  • 6-8 Bar / 0.6-0.8 MPa
  • Door Type
  • Double Walled, Manual / Automatic Sliding
  • Design Pressure
  • 2.5 Bar
  • Working Pressure
  • 1.2 Bar
  • Design Temperature
  • 60C
  • Heat Uniform
  • 2C throughout the Chamber
  • Insulation
  • 50 mm Glass Wool
  • Net Weight
  • Approx. 1300 Kg
  • Recording Parameters
  • Temperature, Pressure, Humidity, EO Concentration
  • Spraying Mode
  • Automatic EO Gas Injection
  • Outer Trolley
  • 304 Stainless Steel, Heavy Duty
  • Inner Trolley
  • 304 Stainless Steel, Modular Design
  • Spraying Piping
  • Stainless Steel 316L
  • Steam
  • Saturated Steam for Pre-Conditioning
  • Sterilizing Temperature
  • 37C to 55C
  • Working Temperature
  • 30C to 60C
  • Sterilization Time
  • 0-24 Hours (Adjustable)
  • Temperature Scope
  • Ambient to 60C
  • Piping System
  • SS 316/316L Piping with Complete Welded Joints
  • Valves
  • Solenoid and Manual Safety Valves
  • Power Consumption
  • 4-6 kW Depending on Size
  • Safety Features
  • EO Leak Detection, Emergency Stop, Overpressure Safety Lock
  • Control System
  • Microprocessor based PLC with Touch Screen HMI
  • Exhaust System
  • Integrated EO Gas Neutralizer/ Scrubber Unit
  • Noise Level
  • <65 dB(A) at 1 Meter
  • Service Access
  • Front and Rear Service Panels for Easy Maintenance
  • Power Supply
  • 220V/380V AC, 50Hz/60Hz
  • Calibration Interface
  • External Ports for Calibration and Validation
  • Installation Type
  • Floor Mounted, Skid Integrated
  • Data Logging
  • USB/Ethernet Connectivity, 21 CFR Compliance
  • Operation Mode
  • Manual/Automatic Selectable
  • Humidity Control Range
  • 30% to 90% RH (Adjustable)
  • Sterilization Agent
  • Pure Ethylene Oxide (EO) / EO+CO2 Mixture
  • Application
  • Medical Devices, Surgical Instruments, Laboratory Use
  • Material of Construction
  • High Grade Stainless Steel 304/316
  • Chamber Door Gasket
  • FDA Approved Silicon Gasket with Leak Proof Sealing
  • Accessories
  • EO Gas Cartridges, Loading Trolley, Spare Filter Set
  • Chamber Finish
  • Mirror Polished Interiors
  • Compliance
  • GMP, CE, ISO 11135 Standards Certified
  • Drying Cabinet Heating
  • Electrically Heated, PID Controlled
 

COMBO Deal : Ethylene Oxide Sterilizer (ETO) and Drying Cabinet Trade Information

  • Minimum Order Quantity
  • 1 Number
  • Delivery Time
  • 15 Days
 

About COMBO Deal : Ethylene Oxide Sterilizer (ETO) and Drying Cabinet

LuxMed https://www.luxmed.in/   Ethylene Oxide (ETO) Sterilizer and a drying cabinet are two distinct but complementary pieces of equipment used in hospitals, laboratories, and medical device manufacturing. The ETO sterilizer eliminates microorganisms on heat-sensitive items, while the drying cabinet removes moisture from equipment to ensure proper sterilization and prevent contamination.

 

ETO Sterilizer (Ethylene Oxide)

ETO sterilizers use ethylene Oxide gas to sterilize medical and surgical devices that cannot withstand high temperatures or moisture (such as catheters, plastic instruments, and delicate optics).

  • Mechanism: The gas penetrates packaging and disrupts the DNA of bacteria, viruses, and fungi without damaging the material.
  • Cycle: Operates under vacuum at low temperatures (typically ( 30C  to (60C)
  • Key Features: Requires automated humidity controls, gas leak detectors, and exhaust systems to safely remove toxic gas residue after sterilization.


Drying Cabinet

Also known as a medical dryer or drying oven, this unit is primarily used to dry large volumes of medical instruments, tubes, and labware before they undergo sterilization.

  • Mechanism: Uses a forced hot-air circulation system that controls heat loss and ensures items are completely bone-dry.
  • Application: Prevents the growth of waterborne bacteria and ensures that residual moisture does not interfere with the efficacy of sterilization processes like ETO or steam.
  • Key Features: Features HEPA-filtered air intakes, adjustable temperature settings (high/medium/low), and modular racks for different instrument sizes. 


Advanced Sterilization Technology

This Combo ETO Sterilizer & Drying Cabinet employs pure EO or EO+CO2 mixtures for highly effective sterilization of medical devices and laboratory instruments. Its microprocessor-based advanced PLC provides precise, programmable control over sterilization cycles, while USB/Ethernet connectivity ensures secure data management, meeting global compliance requirements.


Robust and Hygienic Construction

Both units are constructed with mirror-polished, heavy-duty stainless steel interiors and modular trolley systems for easy cleaning and material handling. FDA-approved silicon gaskets assure leak-proof chamber sealing, and all piping is made of SS 316/316L with glass wool insulation for maximum safety and longevity.


Comprehensive Safety and Monitoring

The system is fortified with EO leak detection, emergency stop, overpressure safety locks, dual-walled doors, and solenoid/manual valves. Built-in calibration ports, external validation interfaces, and 21 CFR-compliant data records guarantee quality assurance and full traceability.

FAQ's of COMBO Deal : Ethylene Oxide Sterilizer (ETO) and Drying Cabinet:


Q: How does the Combo ETO Sterilizer & Drying Cabinet ensure safety during operation?

A: Safety is prioritized with features like EO leak detection, overpressure safety locks, an emergency stop button, and FDA-approved silicon door gaskets. The system is also equipped with solenoid and manual safety valves, as well as a fully integrated EO gas neutralizer/scrubber to protect users and the environment during sterilization cycles.

Q: What types of materials and instruments can be processed with this sterilizer?

A: The Combo system is designed for sterilizing medical devices, surgical instruments, and laboratory equipment. Its adjustable humidity and temperature controls, together with various loading and modular trolley options, accommodate a wide range of materials, ensuring effective sterilization for critical applications.

Q: When should I use EO+CO2 mixture instead of pure Ethylene Oxide (EO) for sterilization?

A: You may choose EO+CO2 mixture for sensitive items or when lower EO concentrations are required, such as for temperature- or humidity-sensitive materials. The system supports both pure EO and EO+CO2 modes, allowing you to optimize sterilization based on specific load requirements and regulatory guidelines.

Q: Where can this Combo Sterilizer & Drying Cabinet be installed?

A: This system is intended for floor-mounted, skid-integrated setups in hospitals, medical device manufacturing facilities, research laboratories, and healthcare centers. With front and rear access panels and compact outer dimensions, it fits into professional environments requiring strict safety and sterility compliance.

Q: What is the process for calibration and validation of the sterilizer?

A: External calibration and validation are facilitated by dedicated interface ports. The system's PLC logs sterilization parameters-temperature, pressure, humidity, and EO concentration-which can be exported via USB or Ethernet, streamlining compliance with 21 CFR, GMP, CE, and ISO 11135 quality standards.

Q: How does the drying cabinet function after the sterilization process?

A: Once the sterilization cycle is completed, instruments are transferred to the electrically heated, PID-controlled drying cabinet. This unit maintains uniform temperatures with adjustable humidity (30% to 90% RH), ensuring thorough drying, reduced cycle times, and optimum readiness for safe reuse.

Q: What are the primary benefits of using this combo sterilizer and drying solution?

A: This integrated combo delivers efficient, safe, and compliant sterilization cycles, enhances operational productivity, streamlines data management, and offers flexibility for both automatic and manual operation. Its robust design and comprehensive safety features reduce maintenance time and ensure longevity of critical sterile assets.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Hospital CSSD Equipment Category

LuxMed Double Door Steam Sterilizer Horizontal

LuxMed Double Door Steam Sterilizer Horizontal

Price 750000.0 INR / Unit

Minimum Order Quantity : 1 Number

Material : SS 304 or SS 316

LuxMed Charging Station

LuxMed Charging Station

Price 650000.0 INR / Piece

Minimum Order Quantity : 1 Number

Material : Steel

Voltage : 110240 Volt (v)

Color : Black

Product Type : Multi Device Charger

LuxMed Table Top Autoclave Sterilizer

LuxMed Table Top Autoclave Sterilizer

Price 350000.0 INR / Unit

Minimum Order Quantity : 1 Number

LuxMed Advanced Double Door Cylindrical Steam Sterilizer

LuxMed Advanced Double Door Cylindrical Steam Sterilizer

Price 550000.0 INR / Piece

Minimum Order Quantity : 1 Number

Material : Stainless Steel

Voltage : 220440 Volt (v)